Saturday, June 14, 2008
Warning: Very large door, larger than the surface.
************** Testing Individual Branch Integrity
************* All Branches passed integrity testing
************* Testing Individual Supply Air Path Integrity
************* All Supply Air Paths passed integrity testing
************* Testing Individual Return Air Path Integrity
************* All Return Air Paths passed integrity testing
************* No node connection errors were found.
*************
************* ===== Recurring Surface Error Summary =====
************* The following surface error messages occurred.
*************
************* Base Surface does not surround subsurface errors occuring...
************* Check that the SurfaceGeometry object is expressing the proper starting corner and direction [CounterClockwise/Clockwise]
*************
** Warning ** Base surface does not surround subsurface (CHKSBS), Overlap Status=Partial-Overlap
** ~~~ ** The base surround errors occurred 1 times.
** ~~~ ** Surface "SYS001:ZN001:WALL001" overlaps SubSurface "SYS001:ZN001:WALL001:DOOR001"
*************
** ~~~ ** The base surround errors occurred 1 times (total).
*************
************* EnergyPlus Completed Successfully-- 4 Warning; 0 Severe Errors; Elapsed Time=00hr 00min 2.00sec
Error: File could not be created

Cause: PDF output and input file are open from a previous simulation. Close PDF files, and generate PDF.
FATAL ERROR -Out Of Bounds
Program Version,EnergyPlus 1.2.1.022, 4/9/2008 5:04 AM,IDD_Version 1.2.1.022
** Severe ** Temperature out of bounds (324.66) for surface=SYS001:ZN001:WALL001
** ~~~ ** in Zone=ZONE01
** ~~~ ** occuring in environment=AHMEDABAD_SDDAY at 05/21 00:60
** ~~~ ** A temperature out of bounds problem can be caused by several things. The user ** ~~~ ** should check the weather environment, the level of internal gains with respect
** ~~~ ** to the zone, and the thermal properties of their materials among other things.
** ~~~ ** A common cause is a building with no thermal mass -- all materials with ** ~~~ ** Regular-R definitions.
** Fatal ** EnergyPlus has exited due to the reason stated above
************* Fatal error -- final processing. More error messages may appear.
************* Testing Individual Branch Integrity
************* All Branches passed integrity testing
************* Testing Individual Supply Air Path Integrity
************* All Supply Air Paths passed integrity testing
************* Testing Individual Return Air Path Integrity
************* All Return Air Paths passed integrity testing
************* No node connection errors were found.
************* EnergyPlus Terminated--Fatal Error Detected. 2 Warning; 1 Severe Errors
Warning that no floor exists in Zone
** Warning ** No floor exists in Zone=ZONE01
************* Testing Individual Branch Integrity
************* All Branches passed integrity testing
************* Testing Individual Supply Air Path Integrity
************* All Supply Air Paths passed integrity testing
************* Testing Individual Return Air Path Integrity
************* All Return Air Paths passed integrity testing
************* No node connection errors were found.
************* EnergyPlus Completed Successfully-- 4 Warning; 0 Severe Errors; Elapsed
Warning if there is no window in the simulation
Program Version,EnergyPlus 1.2.1.022, 4/9/2008 3:09 AM,IDD_Version 1.2.1.022
** Warning ** Sum of area times inside solar abs for all surfaces is zero in Zone: ZONE01
** Warning ** Zone areas*inside surface emissivities are summing to zero
** Warning ** As a result, MRT will be set to MAT for that zone
************* Testing Individual Branch Integrity
************* All Branches passed integrity testing
************* Testing Individual Supply Air Path Integrity
************* All Supply Air Paths passed integrity testing
************* Testing Individual Return Air Path Integrity
************* All Return Air Paths passed integrity testing
************* No node connection errors were found.
************* EnergyPlus Completed Successfully-- 4 Warning; 0 Severe Errors; Elapsed Time=00hr 00min 1.00sec
Normal error file.
************* Testing Individual Branch Integrity
************* All Branches passed integrity testing
************* Testing Individual Supply Air Path Integrity
************* All Supply Air Paths passed integrity testing
************* Testing Individual Return Air Path Integrity
************* All Return Air Paths passed integrity testing
************* No node connection errors were found.
************* EnergyPlus Completed Successfully-- 0 Warning; 0 Severe Errors; Elapsed Time=00hr 00min 2.00sec